conductedBy Bošnjaković, Danko Person Donkó, Zoltan Person Dujko, Sasa Person Hartmann, Peter Person Korolov, Ihor Person Loffhagen, Detlef Person Pinhão, Nuno R. Person Vass, Mate Person
hasTopic basic research Application Field electron swarm parameters Research Topic electron transport Research Topic
investigates Diffusion Drift Ionization Time-of-flight Townsend ionization electron transport Research Topic
usesConfiguration Configuration for scanning drift tube apparatus: Time-of-flight (TOF) experiment; ultraviolet laser light pulse (1.7 µJ, 5 ns) triggered electron generation on Mg disk used as photoemitter; Mg disk placed at the centre of a stainless steel electrode with 105 mm diameter serving as cathode; detector consisting of a grounded nickel mesh and stainless steel electrode 1 mm behind it; drift length between 7.8 to 58.3 mm; reduced electric field range (E/N) between 1 and 1790 Td
usesDevice BK Precision 9185B, BK Precision Device HCA-400M, Femto Diagnostic Device Pfeiffer CMR 362, Pfeiffer Vacuum Diagnostic Device Picoscope 6403B, Pico Technology Diagnostic Device computer Diagnostic Device detector Diagnostic Device photodiode Diagnostic Device rotary pump Device scanning drift tube apparatus Plasma Source turbomolecular pump Device ultraviolet laser Device vacuum chamber Device
usesMethod Data collection Diagnostic Method Monte Carlo simulation Diagnostic Method averaging Diagnostic Method electron Boltzmann calculation Diagnostic Method fitting procedure Diagnostic Method kinetic simulation Diagnostic Method measurements Diagnostic Method swarm map recording Diagnostic Method