The spatial density distribution of H2O2 in the effluent of the COST-Jet and the kINPen-sci operated with a humidified helium feed gas
Plasma Study
Plasma-kg
conductedBy
- Harris, Benjamin Person
- INP Greifswald Institute
- Krös, Levin Person
- Leibniz Institute for Plasma Science and Technology (INP) Institute
- Nave, Andy S. C. Person
- Wagenaars, Erik Person
- van Helden, Jean-Pierre Person
describedIn
hasMedium
- H2O Medium
- He Medium
- Humidified helium Medium
hasOutput
hasPlasmaSource
- COST reference microplasma jet Plasma Source
- COST-Jet Plasma Source
- kINPen-sci Plasma Source
hasTopic
- COST-Jet Research Topic
- H2O2 Research Topic
- Plasma Chemical Processes Research Topic
- absorption spectroscopy Research Topic
- kINPen Research Topic
- plasma jet Research Topic
investigates
involves
- H2O2
- ambient air Medium
- effluent of the COST Jet Plasma
- effluent of the kINPen-sci plasma jet Plasma
usesConfiguration
- Configuration for COST-Jet: sinusoidal waveform of 13.56 MHz with a peak-to-peak voltage of 850 V
- Configuration for coordinate system: The symmetry axis of the plasma effluent is defined as the z-axis, normalised to the tip of the respective jet’s nozzle, such that the effluent exits the source at z = 0
- Configuration for cw-CRDS: Optical cavity composed of two highly reflective mirrors (reflectivity 99.98%, radius of curvature 100 cm), separated by a distance of 54.5 cm; cavity length continuously modulated by 4 μm; quantum cascade laser with a tuning range of 1224 - 1234 cm−1; absorption feature probed within the spectral range of 1231.57 - 1232.00 cm−1
- Configuration for gas medium: Humidified helium containing (3300 +- 100) ppm water at a flow rate of 1 slm at atmospheric pressure
- Configuration for kINPen-sci: sinusoidal waveform of 860 kHz with a peak-to-peak voltage of 3kV
- The kINPen-sci was operated at a sinusoidal waveform of 860 kHz with a peak-to-peak voltage of 3kV. The COST-Jet was operated at a sinusoidal waveform of 13.56 MHz with a peak-to-peak voltage of 850 V.
usesDevice
- Alpes Lasers HHL-223 Diagnostic Device
- Piezosystem Jena RA12-24 Diagnostic Device
- Tektronix AFG 3000 C Diagnostic Device
- Wavelength Electronics PTC5K-CH Diagnostic Device
- Wavelength Electronics QCL1000 Diagnostic Device
- highly reflective mirrors, Lohnstar Optics Diagnostic Device
usesMaterialEntity
- kINPen-sci Plasma Source
usesMethod
- Abel inversion Diagnostic Method
- Cavity Ring-Down Spectroscopy (CRDS) Diagnostic Method
- Continuous Wave Cavity Ring-Down Spectroscopy (cw-CRDS) Diagnostic Method
- cavity-enhanced absorption spectroscopy Diagnostic Method
- model fit Diagnostic Method