diagnosedUsing Alpes Lasers HHL-223 Diagnostic Device Piezosystem Jena RA12-24 Diagnostic Device Tektronix AFG 3000 C Diagnostic Device Wavelength Electronics PTC5K-CH Diagnostic Device Wavelength Electronics QCL1000 Diagnostic Device highly reflective mirrors, Lohnstar Optics Diagnostic Device
diagnosedUsing Abel inversion Method Continuous Wave Cavity Ring-Down Spectroscopy (cw-CRDS) Diagnostic Method cavity-enhanced absorption spectroscopy Diagnostic Method
hasDescription Configuration for coordinate system: The symmetry axis of the plasma effluent is defined as the z-axis, normalised to the tip of the respective jet’s nozzle, such that the effluent exits the source at z = 0
hasProperty Spatial density distribution of H2O2 in the effluent of the kINPen-sci plasma jet: average number density is a factor of two higher than the COST Jet, has a more pronounced radial distribution close to the nozzle, mixing with ambient air is more gradual at further distances from the nozzle
involvedIn The spatial density distribution of H2O2 in the effluent of the COST-Jet and the kINPen-sci operated with a humidified helium feed gas Plasma Study