Upscaling from single- to multi-filament dielectric barrier discharges in pulsed operation
Plasma Study
Plasma-kg
conductedBy
- Becker, Markus M. Person
- Brandenburg, Ronny Person
- Höft, Hans Person
- Kettlitz, Manfred Person
hasMedium
- N2 Medium
- N₂/O₂ mixture Medium
- O2 Medium
hasOutput
hasPlasmaSource
- multi-filament DBD Plasma Source
- single-filament dielectric barrier discharge (DBD) Plasma Source
hasTopic
- basic research Application Field
- scalability of discharge characteristics Research Topic
investigates
involves
- filamentary dielectric barrier discharge Plasma
- streamer discharge Plasma
partOf
usesConfiguration
- Configuration for DBDs operation: Unipolar square wave pulses; Amplitude: 10kV; Repetition frequency: 10 kHz; Rise/fall time: 50 ns; HV pulse width: 0.2 to 50 µs
- Configuration for cameras in multi-filament arrangement: Spatial resolution: ~20 µm
- Configuration for cameras in single filament arrangement: Spatial resolution: ~2 µm
- Configuration for gas flow in multi-filament arrangement: Total gas flow: 300 sccm
- Configuration for gas flow in single-filament arrangement: Total gas flow: 100 sccm
usesDevice
- Andor iStar DH734-18U-A3 Diagnostic Device
- DEIPVX-4110, DEI Device
- Hamamatsu C5680-21C Diagnostic Device
- SGM 7.4, Zirox Diagnostic Device
- Tektronix DPO 7254C Diagnostic Device
- Tektronix P6015A Diagnostic Device
- custom-build 50 Ω resistor Diagnostic Device
- long-distance microscope Diagnostic Device
- mass flow controllers Diagnostic Device
- single-filament dielectric barrier discharge (DBD) Plasma Source
usesMaterialEntity
usesMethod
- Electrical Measurements Diagnostic Method
- Gas admixture and flow control procedure Method
- ICCD Imaging Diagnostic Method
- O2 concentration control Method
- Optical diagnostics Diagnostic Method
- current measurement Diagnostic Method
- pulsed operation Method
- streak camera imaging Diagnostic Method
- voltage measurement Diagnostic Method