multi-filament DBD
Plasma Source
Plasma-kg
diagnosedUsing
- Andor iStar DH734-18U-A3 Diagnostic Device
- Hamamatsu C5680-21C Diagnostic Device
- Tektronix DPO 7254C Diagnostic Device
- Tektronix P6015A Diagnostic Device
- custom-build 50 Ω resistor Diagnostic Device
- long-distance microscope Diagnostic Device
diagnosedUsing
- Electrical Measurements Diagnostic Method
- ICCD Imaging Diagnostic Method
- Optical diagnostics Diagnostic Method
- current measurement Diagnostic Method
- streak camera imaging Diagnostic Method
- voltage measurement Diagnostic Method
generates
- filamentary dielectric barrier discharge Plasma
- streamer discharge Plasma
hasApplicationField
- Basic Research Application Field
hasProperty
hasSpecification
- Specification for DBD: AC, low frequency, atmospheric pressure, non-thermal
- Specification for multi-filament arrangement: positioned in a pumpable stainless steel chamber with a quartz window; 1 mm gas gap; two parallel alumina cylinders with 4 mm outer and 2 mm inner diameter; metal rods of 2 mm diameter inside; dielectric thickness of 1 mm on each electrode; lateral length of the gas gap is about 10 mm
partOf
plasmaSourceOf
usesMedium
- N2 Medium
- N₂/O₂ mixture Medium
- O2 Medium