conductedBy Bošnjaković, Danko Person Donkó, Zoltan Person Dujko, Sasa Person Hartmann, Peter Person Korolov, Ihor Person Loffhagen, Detlef Person Pinhão, Nuno R. Person Vass, Mate Person
hasTopic basic research Application Field electron swarm parameters Research Topic electron transport Research Topic
usesConfiguration Configuration for scanning drift tube apparatus: DC power; low pressure; non-thermal; ultraviolet laser light pulse: 1.7 µJ, 5 ns; cathode diameter: 105 mm; detector-mesh distance: 1 mm; drift length: 7.8 to 58.3 mm; reduced electric field (E/N): 1 to 1790 Td; base pressure: ~1 x 10^-7 mbar; working gas pressure: 5 to 1000 Pa; gas temperature: 293.15 K; averaging: 20000 to 150000 pulses
usesDevice BK Precision 9185B, BK Precision Device HCA-400M, Femto Diagnostic Device Pfeiffer CMR 362, Pfeiffer Vacuum Diagnostic Device Picoscope 6403B, Pico Technology Diagnostic Device photodiode Diagnostic Device rotary pump Device scanning drift tube apparatus Plasma Source turbomolecular pump Device ultraviolet laser Device
usesMethod Averaging Method Monte Carlo simulation Diagnostic Method Time-of-flight (TOF) experiment Diagnostic Method data acquisition procedure Method electron Boltzmann calculation Diagnostic Method fitting procedure Diagnostic Method kinetic simulation Diagnostic Method numerical modelling Method swarm map recording Diagnostic Method