conductedBy Gött, Gregor Person INP Greifswald Institute ISF RWTH Aachen Department Leibniz Institute for Plasma Science and Technology (INP) Institute Lozano, Philipp Person Sharma, Rahul Person Uhrlandt, Dirk Person Zhang, Guokai Person
usesConfiguration Welding parameters: pulsed process in DC-mode, one-drop-per-pulse process, wire 1.2 mm in diameter, wire feed speed 3 to 6 m/min, welding speed 30 cm/min, contact tip setback 3 mm, contact-to-workpiece-distance (CTWD) 9 to 21 mm, peak current (I) 300 to 650 A, base current 25 A, pulse frequency 50 to 130 Hz, pulse duration 1 to 1.5 ms
usesDevice MotionPro Y4 Diagnostic Device Tektronix DPO4104 Diagnostic Device Tektronix TCP404XL Diagnostic Device Tektronix TDP0500 Diagnostic Device