consistsOf Bernard BTB MIG Gun, Bernard Plasma Source contact tip contact tube junction welding torch wire
diagnosedUsing MotionPro Y4 Diagnostic Device Tektronix DPO4104 Diagnostic Device Tektronix TCP404XL Diagnostic Device Tektronix TDP0500 Diagnostic Device
diagnosedUsing Electrical Measurements Diagnostic Method High-Speed Imaging Diagnostic Method arc length determination from high-speed arc images Diagnostic Method current measurement Diagnostic Method voltage measurement Diagnostic Method
hasConfiguration Configuration for Miller Auto-Axcess™ 450: pulsed process in DC-mode, one-drop-per-pulse process, wire 1.2 mm in diameter, wire feed speed 3 to 6 m/min, welding speed 30 cm/min, contact tip setback 3 mm, contact-to-workpiece-distance (CTWD) 9 to 21 mm, peak current (I) 300 to 650 A, base current 25 A, pulse frequency 50 to 130 Hz, pulse duration 1 to 1.5 ms Shielding gas Ar+2.5% CO2, gas flow rate 15 l/min, atmospheric pressure Welding parameters: pulsed process in DC-mode, one-drop-per-pulse process, wire 1.2 mm in diameter, wire feed speed 3 to 6 m/min, welding speed 30 cm/min, contact tip setback 3 mm, contact-to-workpiece-distance (CTWD) 9 to 21 mm, peak current (I) 300 to 650 A, base current 25 A, pulse frequency 50 to 130 Hz, pulse duration 1 to 1.5 ms
hasExperiencedAgent Gött, Gregor Person Lozano, Philipp Person Sharma, Rahul Person Uhrlandt, Dirk Person Zhang, Guokai Person
hasSpecification Specification for Miller Auto-Axcess™ 450: pulsed, DC, low frequency, atmospheric pressure, thermal
plasmaSourceOf A simplified voltage model in GMAW Plasma Study Study of the anode energy in gas metal arc welding Plasma Study
treats CO2 Medium G3Si1 Target Mild Steel Target S235 Target plate Target weld pool Target wire anode Target wire material ER70 S-6 Target workpiece Target
usesMedium Ar Medium Ar+2.5%CO2 Medium CO2 Medium Shielding gas Medium argon shielding gas Medium metal vapour Medium