DBD
Plasma Source
Plasma-kg
diagnosedUsing
- Fluid-Poisson Model Diagnostic Method
- current measurement Diagnostic Method
- fluid modelling Method
- voltage measurement Diagnostic Method
generates
- dielectric barrier discharge Plasma
- discharge plasma Plasma
hasApplicationField
- Film Deposition Application Field
- PECVD Application Field
- plasma-polymerization Application Field
hasConfiguration
- Atmospheric pressure DBD between plane electrodes covered by dielectrics (glass and Macor); Powered electrode: Macor covered, thickness of dielectric: 3.5 mm; Grounded electrode: glass covered, thickness of dielectric: 3.0 mm; Discharge gap: 2 mm; Discharge area: 216 cm^2; Voltage supply: sinusoidal voltage with amplitude of 3.9 kV and frequency of 20 kHz; RMS current: about 50 mA
- Configuration for DBD: Atmospheric-pressure DBD between plane steel mesh electrodes covered by dielectrics (borofloat glass, relative permittivity: 4.6); Electrode area: 8 cm^2; Thickness of dielectrics: 2 mm; Discharge gap: 1 mm; Voltage supply: sinusoidal voltage with variable amplitude and frequency of 86.2 kHz
hasDescription
hasDeviceType
- Dielectric Barrier Discharge (DBD) Plasma Source Type
hasExperiencedAgent
- Becker, Markus M. Person
- Czerny, Andreas K. Person
- Klages, Claus-Peter Person
- Loffhagen, Detlef Person
hasProperty
hasSpecification
plasmaSourceOf
usesMaterialEntity
- Voltage supply Device
usesMedium
- Ar Medium
- HMDSO Medium
- argon-HMDSO mixtures Medium