consistsOf HCA-S, Femto Diagnostic Device Michelson–Morley interferometer WSG-200, High Finesse Diagnostic Device acousto-optic modulator grating laser diode
hasConfiguration Configuration for laser atomic absorption spectroscopy setup: Laser wavelength: 811.534 nm; Laser linewidth: ~15 fm; Laser power at target: ~50 μW; Focus spot size: ~100 μm; Bandpass filter: 10 nm at 810 nm
hasExperiencedAgent Bansemer, Robert Person Brandenburg, Ronny Person Klose, Sarah-Johanna Person van Helden, Jean-Pierre Person
hasSpecification Specification for EasyLAAS laser system: Laser wavelength: 811.534 nm; Laser linewidth: ~15 fm (0.0002 cm⁻¹); Tuning range: ~50 GHz; Frequency: 4.5 GHz
usedIn Extended reaction kinetics model for non-thermal argon plasmas and its test against experimental data Plasma Study Investigation of Ar(³P₂) metastable density in the effluent of a filamentary atmospheric pressure plasma jet with humidified feed gas Plasma Study Investigation of the spatial distribution of HO₂ in an atmospheric pressure plasma jet by cavity ring-down spectroscopy Plasma Study
usedToDiagnose Ar(³P₂) metastables Venturi-DBD (VDBD) Plasma Source effluent filamentary atmospheric pressure Argon plasma Plasma weakly ionised, non-thermal argon plasmas Plasma