partOf
- Configuration for PJAS I-1: Device I (homemade integrated circuit, 66 V DC from base unit); Valve Setting 1 (8 ms flushing per channel, 8.2-8.3 ms programming delay); Frequency ~1 MHz; Voltage 3-6 kV ptp; Pressure 1 atm; Argon pre-pressure 5 bar; Argon flow rate 2.5 slm or 5 slm
- Configuration for PJAS I-2: Device I (homemade integrated circuit, 66 V DC from base unit); Valve Setting 2 (30 ms valve opening, 2 ms delay); Frequency ~1 MHz; Voltage 3-6 kV ptp; Pressure 1 atm; Argon pre-pressure 5 bar; Argon flow rate 2.5 slm or 5 slm
- Specification for Plasma Jet Array System Device I: Waveform: DC; Frequency range: High Frequency (~1 MHz); Voltage range: 3-6 kV ptp; Pressure range: Atmospheric pressure; Temperature range: non-thermal; Technology: Gas switching technology with homemade integrated circuit; Input voltage: 66 V DC